Bulk Microwave Cable

DC to 40Ghz

Features and Advantages

Low Density ePTFE tape dielectric allows to obtain velocity of propagation up to 83%. SPC(Silver Plated Copper) tape and braids will increase shielding effectiveness. FEP jacket allows chemical resistance and protects from environment.

Features and Advantages

Low Density ePTFE tape dielectric allows to obtain velocity of propagation up to 83%. SPC(Silver Plated Copper) tape and braids will increase shielding effectiveness. FEP jacket allows chemical resistance and protects from environment.

PHYSICAL & ENVIRONMENTAL (Mechanical units are in mm)
SPECIFICATIONS E14 LH31 LH21
Solid Center Conductor 0.93 2.3 1.4
Dielectric Core 2.5 6.3 4.10
Outer Shield (2nd) 3.1 7.25 4.70
Outer Diameter 3.6 7.9 5.6 ±0.1
Impedance (ohm) 50 ± 1 ohm 50 ± 1 ohm 50 ± 1 ohm
Velocity of Propagation 83% nom. 83% nom. 76% nom.
Bending Radius 18mm 35mm 30mm
RF Leakage < –100 < –100 < –100
Operating Temp (℃) –45~+125 –45~+125 –45~+125
Jacketing Grey FEP Grey FEP Black FEP
Phase Stability vs. Flexure (@ 18Ghz Max) ±3.6° ±5.0° ±5.0°
Amplitude Stability ±0.15dB max ±0.15dB max ±0.15dB max
ATTENUATION (db/m) & POWER HANDLING (w) @ + 25℃ (Sea level)
FREQUENCY (GHz) E14 LH31 LH21
1 0.36 db/m 625 W 0.15 db/m 1600 W 0.08 db/m 1025 W
6 0.86 db/m 255W 0.37 db/m 650W 0.20 db/m 416 W
10 1.10 db/m 198 W 0.49 db/m 550 W 0.27 db/m 318 W
18 1.58 db/m 145 W 0.68 db/m 380 W 0.38 db/m 235 W
26.5 2.09 db/m 115 W 0.47 db/m 175 W
40 2.64 db/m 85 W

ⓒ 2016. OPTIMUM SOLUTIONS INTERCONNECTS all rights reserved.